How to Program the 2GIG-DW10E-345 to the GC2 Panel

Follow the steps below to connect the 2GIG DW10E-345 door/window sensor to the 2GIG GC2 panel.


1. Press the bottom right logo, enter the default installer code 1561 or 1171, then press system configuration.

001a_Enter_Programming_Mode_-_Programming_-_Enter_Program_01_278x158.png 001b_User_Menu_-_Disarm_05_278x158.png 001c_Programming_-_Enter_Program_03_278x158.png


2. From here, you've entered Q1: RF sensor programming. Press go to, enter a 2-digit location number between 01 and 60, then press the down arrow to continue.

002a_Programming_-_Enter_Program_04_278x158.png 002b_2GIG_Q2_Wired_Programming_1_Select_280x159.png 002c_Programming_-_Enter_Program_05_278x158.png


3. To select your sensor type, enter 01, 02, or 03, or press the arrow buttons to scroll through the following options: (01) Exit/Entry 1, (02) Exit/Entry 2, or (03) Perimeter. Next, press the down arrow to continue.

002a_2GIG_Q1_RF_Sensor_Programming_02_Type_278x158.png


4. To specify the equipment type, press the arrow buttons to scroll to (0862) 2GIG Door/Window Contact, or if encrypted, scroll to (2862) eSeries Door/Window Contact. Press the down arrow to continue.

003a_2GIG_Q1_RF_Sensor_Programming_02_Equipment_Code_0862_Door_Sensor_278x158.png


5. Enter the serial number from the sensor sticker. Alternatively, you can press shift, then press learn, then tamper/activate the sensor, and then press ok. Once the serial number is entered manually or through the alternative process, press the down arrow to continue.

004a_2GIG_Q1_RF_Sensor_Programming_05_Serial_Number_1_278x158.png 004b_2GIG_Q1_RF_Sensor_Programming_05_Serial_Number_2_278x158.png 004c_2GIG_Q1_RF_Sensor_Programming_05_Serial_Number_3_278x158.png


6. Enter 0, then press the down arrow to continue.

006a_2GIG_Q1_RF_Sensor_Programming_06_Equipment_Age_278x158.png


7. Enter 1 if using an external switch or 2 if using an internal reed switch, then press the down arrow to continue.

007a_2GIG_Q1_RF_Sensor_Programming_07_Loop_Number_278x158.png


8. Enter 1 to enable the 30-second dialer delay, then press the down arrow to continue.

008a_2GIG_Q1_RF_Sensor_Programming_08_Dialer_Delay_278x158.png


9. Press insert and use the arrows to select a voice descriptor for the sensor, then press the down arrow to continue. Note: multiple words can be added by pressing insert again.

009a_2GIG_Q1_RF_Sensor_Programming_09_Description_1_Blank_278x158.png 009b_2GIG_Q1_RF_Sensor_Programming_09_Description_2_Front_278x158.png


10. Enter 1 to enable central station reports, then press the down arrow to continue.

011a_2GIG_Q1_RF_Sensor_Programming_10_Reports_278x158.png


11. Enter 1 to enable sensor supervision, then press the down arrow to continue.

012a_2GIG_Q1_RF_Sensor_Programming_11_Supervision_278x158.png


12. Press the arrow buttons to scroll through numbered chime sounds, then press the down arrow to continue.

013a_2GIG_Q1_RF_Sensor_Programming_12_Chime_278x158.png


13. Press the down arrow to complete the process or press edit next to program in the next sensor.

014a_2GIG_Q1_RF_Sensor_Programming_13_Summary_1_278x158.png


If you need further assistance, you can text a Support Representative any time at 469.513.8685.